In hazardous production areas, safety is critical. For Zone 1/21 and Division 1 classified areas, the intrinsically safe IND500x weighing indicator delivers process control and versatility, enabling the perfect balance of safety and maximum productivity. Optimize your manual, automatic or semi-automatic application with IND500x.
This terminal is available worldwide and well-suited for the Chemical, Cosmetics, and Pharmaceutical industries.
Description
IND500x Hazardous Area Terminal Specifications
Specifications |
|
Enclosure Type and Dimensions |
Harsh enclosure (type 304 stainless steel ): 289 x 184 x 162 mm (7.2 x 11.4 X 6.4 in.), VESA100 |
Keypad |
(PC) display lens |
Display |
4.3″ TFT color display (480 x 272), with 20 mm high weight display |
Clock Accuracy |
< 1 second / day (without time server access) at 25° C consistent room temperature |
Shipping Weight |
4.0 kg / 8.8 lb (net weight) |
Environment Protection |
Harsh Environment enclosure meets IP65 requirements |
Power |
APS768x power supply with intrinsically safe outputs |
Supported scale types |
One scale interface for Analog or Digital (SICSPro or IDNet) Platform |
Analog Scale Interface |
Load Cell Excitation Voltage: 4.8 VDC Minimum Sensitivity: 0.3μV/e approved, up to four 350 Ohms load cells, 1-3 mV/V” |
Analog/Digital Update Rates |
Internal: Analog: >366 Hz; IDNet: determined by base; SICSpro: 50 Hz for bases that include Advanced Setup Mode; Target Comparison: up to 50 Hz |
Weight Display |
Displayed resolution of 100,000 counts for analog load cell scales Display resolution for IDNet and SICSpro bases is determined by the specific base used |
Standard Interfaces |
One intrinsically safe RS-232 serial port (COM1), 300 to 115,200 baud (maximum cable length: 10 m /32.8 ft) Discrete I/O with 3 active inputs and 3 passive outputs |
Optional Interfaces |
Discrete I/O interface with 5 inputs and 8 outputs intrinsically safe RS-232 serial port (COM6), 300 to115,200 baud (maximum cable length: 10 m / 32.8 ft) Intrinsically safe 4-20mA analog output interface (maximum cable length: 300 m / 984.3 ft) Dual-channel intrinsically safe active current loop interface to communicate with ACM200 or ACM500 (maximum cable length: 300 m / 984.3 ft) Fiber optic interface (to communicate with ACM500) (maximum cable length: 300 m / 984.3 ft) |
Data and PLC Interfaces |
RS-232, RS-422/RS-485 provided by ACM200 located in the non-hazardous area Ethernet TCP/IP, RS-232, RS-422/RS-485 and PROFINET, Profibus DP, EtherNet/IP, Modbus TCP provided by ACM500 located in the non-hazardous area |
Protocols |
Serial Inputs: ASCII commands for CTPZ (Clear, Tare, Print, Zero), SICS (most level 0 and level 1 commands), and Shared Data Server Access Serial Outputs: Continuous or Demand with up to ten configurable print templates or SICS host protocol , report printing PROFINET: SAI™ (Standard Automation Interface SAI) 1, 2 and 4-Block format (2 recommended) certification certificate Z13186 Profibus DP and EtherNet/IP: IND560 Shared Data Protocol Modbus TCP: IND560 compatible protocol |
Weight display: |
25 Hz |
Interface and Function Update Rates |
Internal discrete I/O: 50 Hz SICS continuous (SIR): up to 20 Hz Continuous Template (Eprint): 20 Hz Continuous Template (serial): 18 Hz (115.2Kbaud), 14 Hz (38.4Kbaud) PLC cyclic data: 25 Hz External discrete I/O (ARM100): 25 Hz MT Continuous Output: up to 20 Hz |
Operating Environment |
-10° to 40° C (14° to 104°F), 10% to 95% relative humidity, non- condensing |
Storage Environment |
-20°C to 60° C (-4° to 140°F), 10% to 95% relative humidity, non- condensing |
Approvals |
Weights & Measures USA: NTEP Class II 100,000d; Class III/IIIL 10,000d Canada: Class II 100,000d; Class III 10,000d; Class IIIHD, 10,000d Europe: OIML R76 Class II approved divisions determined by platform; Class II 100,000e, Class III 10,000e and Class IIII 1,000e; MID R61 (Automatic Gravimetric Filling Instrument); MID R51 (Automatic Catchweigher) |
Hazardous Locations ATEX, Zone 1 and Zone 21, FM21ATEX0033X II 2 G Ex ib [op is Ga] IIC T4 Gb; II 2 D Ex ib tb [ib] [op is Da] IIIC T60°C Db; Tamb = -10°C to +40°C IECEx, Equipment Protection Level Gb and Db, IECEx FMG 21.0022X Ex ib [op is Ga] IIC T4 Gb; Ex ib tb [ib] [op is Da] IIIC T60°C Db: IP65; Tamb = -10°C to +40°C FMus for US, DIV 1 and Zone 1 and Zone 21, FM21US0064X IS Class I, II, III, Division 1, Groups A, B, C, D, E, F, G; T4; Class I, Zone 1, AEx ib [op is Ga] IIC T4 Gb; Zone 21, AEx ib [op is Da] IIIC T60°C Db; IP65; Tamb = -10°C to +40°C cFM for Canada, DIV 1 and Zone 1 and Zone 21, FM21CA0040X IS Class I, II, III, Division 1, Groups A, B, C, D, E, F, G; T4 Ex ib [op is Ga] IIC T4 Gb; Ex ib [op is Da] IIIC T60°C Db; IP65; Tamb = -10°C to +40°C” |