IND256x Intrinsically Safe Weighing Terminal

The IND256x intrinsically safe weighing terminal is cost effective and site-friendly. Designed to operate safely in environments with explosive gases or dusts, the economical IND256x meets cFMus, ATEX and IECEx hazardous area approvals.

  • Easy scale mobility using external NiMH battery
  • Simplified data transfer using intrinsically safe WiFi
  • Efficient and cost-saving communication in process application is enabled by an intrinsically safe 4-20 mA analog output interface
  • Flexible workplace location thanks to WiFi connectivity
  • Easy cleanability and protection against corrosion and ingress for most industrial environments

Contact us for pricing.

Description

IND256x Intrinsically Safe Weighing Terminal Specifications

METTLER TOLEDO IND256x intrinsically safe weighing terminal

 

Dimensions (HxWxD) 173 mm × 230 mm × 127 mm (6.8 in. × 9.1 in. × 5.0 in.)
Construction AISI 304 Stainless Steel
Power AC: APS500 (85-132 V, 50/60 Hz); APS501 (168-250 V, 50/60 Hz)
Battery: External NiMH, charged in safe area. External charger sold separately.
Mounting Desk, wall or column
Storage Environment Storage temperature range: –20°C to 60° C (–4° to 140°F). Relative humidity: 10% to 95%, non-condensing
Service Environment Operating temperature range: –10°C to 40° C (14° to 104°F). Relative humidity: 10% to 95%, non-condensing
Protection IP66
Display 240 x 96 pixel white backlit LCD, 25mm high digits. Display update rate: 10 Hz
Weight Display Maximum 100,000 divisions
Scale Interface Analog, 4 x 350Ω, 2-3 mV/V
Weight Update Rate >366 Hz
Load Cell Excitation 4.5 VDC
Keypad 26 keys; 1.5mm thick membrane keyboard
Alibi Memory Storage for up to 60,000 records
Communication Standard One intrinsically safe RS-232 interface included on mainboard
  Interface Intrinsically safe Analog Output: 16-bit D/A conversion with 25 Hz update rate to PLC, or
  Options Intrinsically safe active current loop, or
  Intrinsically safe passive current loop
  Protocols Serial port input: ASCII commands – CTPZ (Clear, Tare, Print, Zero), SICS commands (supports SICS levels 0 and 1)
  Serial port output: Toledo continuous output, demand print output (5 configurable templates), SICS responses and report print
Metrology US NTEP: Class III/IIIL, nmax=10,000; CC No.: 18-099

Canada: Class III/IIIHD, nmax=10,000; AM-6115

Approvals FM

 

Non Wi-Fi version

Only with intrinsically safe external power supply or battery

IS CL I,II,III/DIV 1/GP ABCDEFG/T4

CL I, Zone 1 AEx/Ex ib IIC T4 Gb

Zone 21 AEx/Ex tb [ib] IIIC T60°C Db

  Factory-configured WiFi version

Only with intrinsically safe external power supply or battery

 

IS CL I,II,III/DIV 1/GP CDEFG/T4

CL I, Zone 1, AEx/Ex ib IIB T4 Gb

Zone 21, AEx/Ex tb [ib] IIIC T60°C Db

 

  FM-US Cert. No.:

FM-Canada Cert. No.:

 

FM18US0258X