The IND256x intrinsically safe weighing terminal is cost effective and site-friendly. Designed to operate safely in environments with explosive gases or dusts, the economical IND256x meets cFMus, ATEX and IECEx hazardous area approvals.
- Easy scale mobility using external NiMH battery
- Simplified data transfer using intrinsically safe WiFi
- Efficient and cost-saving communication in process application is enabled by an intrinsically safe 4-20 mA analog output interface
- Flexible workplace location thanks to WiFi connectivity
- Easy cleanability and protection against corrosion and ingress for most industrial environments
Contact us for pricing.
Description
IND256x Intrinsically Safe Weighing Terminal Specifications
Dimensions (HxWxD) | 173 mm × 230 mm × 127 mm (6.8 in. × 9.1 in. × 5.0 in.) | ||||
Construction | AISI 304 Stainless Steel | ||||
Power | AC: APS500 (85-132 V, 50/60 Hz); APS501 (168-250 V, 50/60 Hz) | ||||
Battery: External NiMH, charged in safe area. External charger sold separately. | |||||
Mounting | Desk, wall or column | ||||
Storage Environment | Storage temperature range: –20°C to 60° C (–4° to 140°F). Relative humidity: 10% to 95%, non-condensing | ||||
Service Environment | Operating temperature range: –10°C to 40° C (14° to 104°F). Relative humidity: 10% to 95%, non-condensing | ||||
Protection | IP66 | ||||
Display | 240 x 96 pixel white backlit LCD, 25mm high digits. Display update rate: 10 Hz | ||||
Weight Display | Maximum 100,000 divisions | ||||
Scale Interface | Analog, 4 x 350Ω, 2-3 mV/V | ||||
Weight Update Rate | >366 Hz | ||||
Load Cell Excitation | 4.5 VDC | ||||
Keypad | 26 keys; 1.5mm thick membrane keyboard | ||||
Alibi Memory | Storage for up to 60,000 records | ||||
Communication | Standard | One intrinsically safe RS-232 interface included on mainboard | |||
Interface | Intrinsically safe Analog Output: 16-bit D/A conversion with 25 Hz update rate to PLC, or | ||||
Options | Intrinsically safe active current loop, or | ||||
Intrinsically safe passive current loop | |||||
Protocols | Serial port input: ASCII commands – CTPZ (Clear, Tare, Print, Zero), SICS commands (supports SICS levels 0 and 1) | ||||
Serial port output: Toledo continuous output, demand print output (5 configurable templates), SICS responses and report print | |||||
Metrology | US NTEP: Class III/IIIL, nmax=10,000; CC No.: 18-099
Canada: Class III/IIIHD, nmax=10,000; AM-6115 |
||||
Approvals | FM
|
Non Wi-Fi version
Only with intrinsically safe external power supply or battery |
IS CL I,II,III/DIV 1/GP ABCDEFG/T4
CL I, Zone 1 AEx/Ex ib IIC T4 Gb Zone 21 AEx/Ex tb [ib] IIIC T60°C Db |
||
Factory-configured WiFi version
Only with intrinsically safe external power supply or battery
|
IS CL I,II,III/DIV 1/GP CDEFG/T4
CL I, Zone 1, AEx/Ex ib IIB T4 Gb Zone 21, AEx/Ex tb [ib] IIIC T60°C Db
|
||||
FM-US Cert. No.:
FM-Canada Cert. No.:
|
FM18US0258X
FM18CA0123X |