Designed for dry environments
The ICS445 scale terminal with basic counting solutions has been designed for real industrial counting. Configurable soft keys for fast access to key functions such as sampling for counting offer easy and fast operation. A second digital or analog scale interface, which is available as an option, can be used to connect a second weighing platform in order to create a cost-effective two-scale counting system.
Description
METTLER TOLEDO ICS445 Scale Terminal Specifications
Terminal | ICS445 |
Application/Features | Basic weighing, Average Weighing / Date & Time and Printing, Counting, Alibi / Transaction Memory, softkeys and User Prompting |
Dimension & Type | 248.5x164x78 mm / 9.78×6.46×3.71 in
Diecast aluminum |
Display | LCD liquid crystal graphical display with backlighting |
Character height | Default layout mode = 20 mm, 3-line info mode = 15 |
Languages | English, German, French, Italian, Spanish, Chinese |
Keypad | Tactile-touch membrane keypad (PET), scratch-resistant material |
Numeric keypad | No |
Net Weight | 2 kg / 4.4 lb |
Shipping Weight | 2.5 kg/ 5.5 lb |
Mains connection | 100 -240 V / 50 – 60 Hz / 300 mA, Power cord approx. 2.5 m |
Optional internal battery | 12 VDC / 2.5 A
1 strain gauge weighing cell continuous operation ~ 15 h (less with installed options) 4 strain gauge weighing cells continuous operation ~ 12 h (less with installed options) |
Temperature Range | Class III –10 – 40 °C / 14 – 104 °F (Strain gauge)
Class II 10 – 30 °C / 50 – 86 °F (MonoBloc®) |
Humidity | Max. rel. humidity 85 % for temperatures up to 40 °C |
Data Interfaces | 1 x Standard RS232
1 x Optional* |
*Choose from the following interfaces: RS232, RS422/485, USB device/host, Ethernet, WLAN,
Digital I/O, digital or analog 2nd scale |
|
Connectable platforms | 2 scales can be connected
all analog & SICS platforms |
Analog scale connection | Impedance: ≥ 80 Ω (means 1 x 350 Ω; 4 x 350 Ω), Excitation: 3.3 VDC, Sensitivity: 2 to 3 mV/V
Max. Resolution: 7500e (OIML), 300 000d (non approvable), Min. verification interval: 0.5 μV/e |
Approvals | The Weights & Measures data is shown on the display.
The display indicates if the system is approved or not. Approvals are: OIML, NTEP, IP65, CE, CSA |
Accessories | Cable with plugs for offered interfaces, Stand (height 330 mm), Wall bracket,
Printers (Sprinter; P25; P26), Cover for terminal, Battery charger, Auxiliary display, Relay module Power supply with 9-28VDC |